Product Details:
Payment & Shipping Terms:
|
Type: | Adjustable Ball Valve Lockout | Material: | Polypropylene PP |
---|---|---|---|
Color: | Red,Other Colors Need To Be Customized | Usage: | Industrial, Electrical |
Weight: | 134g | Suit For: | DN8-DN200 Ball Valve |
Customer Logo: | Yes, Can Laser Or Print Customers Logo | Devices: | Durable Valve Loto Devices |
Red Color Adjustable Ball Valve Lockout With Tagout Suit for DN8-DN20 Ball Valve
Features:
ZC-F01 Adjustable ball valve lockout
1. Made from polypropylene PP.
2. Applied Sizes:
a. ZC-F01 locks out pipes from 13mm (1/2") to 64mm (2 1/2") in diameter.
b. ZC-F02 locks out pipes from 50mm (2") to 200mm (8") in diameter.
c. Padlock locked shackle max diameter: 9mm.
d. Color: red, other colors need to be customized.
Specification:
Item no. | Description |
ZC-F01 | suitable for 13mm (1/2'') to 64mm (2 1/2'') pipes |
ZC-F02 | suitable for 50mm (2") to 200mm (8") pipes |
Related Valve Lock Out:
ZC-F01 | Small lockout locks out pipes from 13mm to 64mm in diameter | ||||||||
ZC-F02 | Large lockout locks out pipes from 50mm to 200mm in diameter | ||||||||
ZC-F03 | Small lockout suitable for 1/4'' to 1'' pipes in diameter | ||||||||
ZC-F04 | Large lockout locks out pipes from 1 1/2'' to 3'' in diameter | ||||||||
ZC-F05 | Adjustable Ball Valve Lockout , Suitable for 13-70mm pipes | ||||||||
ZC-F05A | Adjustable Ball Valve Lockout , with auxiliary parts | ||||||||
ZC-F06 | Adjustable Ball Valve Lockout , Suitable for 13-70mm pipes | ||||||||
ZC-F06A | Adjustable Ball Valve Lockout , Suitable for DN50-DN70, with auxiliary parts | ||||||||
ZC-F07 | Adjustable Ball Valve Lockout , Suitable for 73-215mm pipes | ||||||||
ZC-F08 | Adjustable Ball Valve Lockout , Suitable for DN8-DN125 ball valve | ||||||||
ZC-F11 | Lockout suitable for 1" --- 2 1/2" valve rod | ||||||||
ZC-F12 | Lockout suitable for 2 1/2" ---5" valve rod | ||||||||
ZC-F13 | Lockout suitable for 5" --6 1/2" valve rod | ||||||||
ZC-F14 | Lockout suitable for 6 1/2"---10" valve rod | ||||||||
ZC-F15 | Lockout suitable for 10" --13" valve rod | ||||||||
ZC-F11A | Lockout suitable for 1" --- 2 1/2" valve rod | ||||||||
ZC-F12A | Lockout suitable for 2 1/2" ---5" valve rod | ||||||||
ZC-F13A | Lockout suitable for 5" --6 1/2" valve rod | ||||||||
ZC-F14A | Lockout suitable for 6 1/2"---10" valve rod | ||||||||
ZC-F15A | Lockout suitable for 10" --13" valve rod |
Usage:
1. Perform daily maintenance on the equipment, maintenance, adjustment, cleaning, checking and debugging
2. Operation under high pressure
3. The operation that needs to temporaily turn off the security system
4. Widely used in petrochemical, chemical, nuclear power, military automobile shipbuilding industries, suitable for oil pipelines, cable interlayer, platform channel, pump house, Tunnel Project, Mountain-climbing,Hiking, Patrolling, Overhauling and Emergency in electrical power company,Mine, Military, Police, Fire Fighting, Dockyard and other hazardous.
Our products cover:
Safety padlock, Pneumatic Lockout, Safety Lockout HASP, Electrical Lockout, Valve Lockout, Lockout Station, Cable Lockout, Tagout & Label.
About the samples:
If you are really interested in our products, kindly send us an email to get a competitive price quote.
You also can order a sample for testing or promotion, in advance of any large commitments.
We merely ask that you provide the sample material cost and freight fee.
Once you place a subsequent bulk order, we will refund the sample material cost!
Sample Delivery Time : 3-5 Working Days.
Why Use Lockout/Tag out
Due to the hight rate of industrial accidents caused by unexpected organization, start up od machines or equipment, uncontrolled release of energy, reducing the industrial accidents becomes one of today’s most serious issues. LOCKOUT/TAGOUT is a planned safety procedure that disables the energy supply of industrial machinery and equipment whilst servicing, maintenance work or repairs are in progress. Many of industrial accidents can be prevented by proper LOCKOUT/TAGOUT procedures.
Making the right kind of LOCKOUT & TAGOUT equipment available to the employee is the responsibility of the plant’s management.
Where use LOCKOUT/TAGOUT?
1.Perform daily maintenance on the equipment,adjustment,cleaning,inspection and debugging etc.
2.Operation under high pressure
3.The operation that needs to temporarily turn off the security system.
4.Widely used in petrochemical,chemical,nuclear power,military automobile ship building industries,suitable for oil pipelines,cable interlayer,platform channel,pup house,Tunnel Project,Mountain-climbing,Hiking,Patrolling,Overhauling and Emergency in electrical power company,Mine,Military,Police,Firefighting,Dockyard and other hazardous locations.
LOCKOUT/TAGOUT Requirements
1.If more than one individual is required to work on a particular piece of equipment,each shall place his own personal LOCKOUT/TAGOUT device on the energy isolating devices.
2.Never authorize to other employees to remove your LOGO devices.
3.During work shift,never remove your LOCKOUT/TAGOUT devices before another to confirm the LOCKOUT/TAGOUT devices are safety and then begin operations.
4.Each LOCKOUT/TAGOUT device with the name of the employee for operations.
Each employee can't continue operations depend on others' LOCKOUT/TAGOUT devices.
5.Proper application and utilization of LOCKOUT/TAGOUT devices.
6.A periodic inspection of the energy control procedures shall be conducted at least annuanlly to ensure that the procedure and the requirments of this standard are being followed.
7.If there is a poss ability of re-accumulation no longer exists.
8.Outside person,such as contractors,must be aware of the LOTO procudures of the Company.This is best accomplished with outside person during the initial meeting where a copy of the Company's LOTO program can be presented and discussed along with oher safety program requirments.
Applications
1.Learn well how to use the equipment.
The quthorized employee shall know well the power supply equipment's position.performance and how to control the power source LOCKOUT/TAGOUT procedure also will present which power source,switch need lockout.And please comply with the LOCKOUT/TAOUT procedure on devices
2.Notify personnel.
Notify all relative operators before setting LOCKOUT/TAGOUT devices to avoid error operating accidents.
3.Shutdown equipment
Power switch off,or in a state of grounding,and apply TAGOUT to warn others.
4.De-Energize and lock power source.
Use LOCKOUT/TAGOUT for hazardous power source,e.g. use circuit breaker lockout to lock the circuit breaker or valve lockout to lock valve.
5.Release stored energy.
Must release stored energy before maintaining.The release stored energy is hidden may cause personal injury in the case of unknown the equipment starts up suddenly.
6.Verify zero energy state
In any case,in the event of the change of LOCKOUT/TAGOUT,it must be assured that the device is at zero energy state before work resumes.This step must be operated by authorized person,the verification results of other employee are regarded as invalid.
7.Restor the LOCKOUT/TAGOUT devices
Please restoring the LOCKOUT/TAGOUT devices immediately after testing,If it needs to remove the LOCKOUT/TAGOUT devices for equipment testing.
8.Remove LOCKOUT/TAGOUT devices
Work completed,before remove LOCKOUT/TAGOUT devices,please ensure nobody around the machines or equipment and notify relevant persons this equipment will re-startup.Only authorized employees can remove LOCKOUT/TAGOUT devices.
Our company
Why choose Zhou Chuang ?
About us
Some of our strengths that make us your most reliable business partner are:
1) Extensive industry knowledge / experience
2) Wide range of products for diverse applications in various industry segments
3) Our comprehensive quality policy
4) Reliable, well-organized and efficient distribution network
5) Competitive prices
6) Our stable business model, robust finance,honest value system and customer-centric approach.
Warranty and ater-sales service
1) Warranty: 1 years, for defective one, we will replace a total new cap lamp during warranty time
2) After sales service: will deal with your complaint at first time, give you solution within 5 working days
3) Free samples: free samples will be provided when our new models come out
4) Market support: we can support you to do advertisment in local magazine and provide samples with
big discount for exhibition
Packing &Delivery
10Pcs/Box 20Pcs/Carton 20kg/Carton
We can customized the package for our customer,any requirements welcome to tell us.
FAQ
1. If you couldn’t find the exact product you want, never mind, just contact us and tell your requirements, we will arrange the moulds and manufacture for you.
2. No minimum order quantity required
3. Many products are available from stock with the next several days.
4. If required, goods can be collected from our factory directly to your customers.
5. We also support OEM manufacturing, with any given order quantity.
Contact us
Shen Zhen Zhou Chuang Technology Co., Ltd
Add: No.2 Bldg,Da Pu Industrial,Long Dong Community,Long Gang District, Shen Zhen City, China.
Tel: +86-755-84829400 Fax:+86-755-84820206
Cell: +86 13603090255
Skype: glsafety08@outlook.com E-mail: sales8@zhouchuangsz.com
Website: http://www.zhouchuangsz.com